501 research outputs found

    Remote preparation of arbitrary ensembles and quantum bit commitment

    Full text link
    The Hughston-Jozsa-Wootters theorem shows that any finite ensemble of quantum states can be prepared "at a distance", and it has been used to demonstrate the insecurity of all bit commitment protocols based on finite quantum systems without superselection rules. In this paper, we prove a generalized HJW theorem for arbitrary ensembles of states on a C*-algebra. We then use this result to demonstrate the insecurity of bit commitment protocols based on infinite quantum systems, and quantum systems with Abelian superselection rules.Comment: 21 pages, LaTeX. Version 2: Proofs expanded and made more self-contained; added an example of a bit commitment protocol with continuous ensemble

    Temporal pixel multiplexing for simultaneous high-speed, high-resolution imaging

    Get PDF
    We introduce an imaging modality that, by offsetting pixel-exposure times during capture of a single image frame, embeds temporal information in each frame. This allows simultaneous acquisition of full-resolution images at native detector frame rates and high-speed image sequences at reduced resolution, without increasing bandwidth requirements. We demonstrate this method using macroscopic and microscopic examples, including imaging calcium transients in heart cells at 250 Hz using a 10-Hz megapixel camera

    Effects and Propositions

    Full text link
    The quantum logical and quantum information-theoretic traditions have exerted an especially powerful influence on Bub's thinking about the conceptual foundations of quantum mechanics. This paper discusses both the quantum logical and information-theoretic traditions from the point of view of their representational frameworks. I argue that it is at this level, at the level of its framework, that the quantum logical tradition has retained its centrality to Bub's thought. It is further argued that there is implicit in the quantum information-theoretic tradition a set of ideas that mark a genuinely new alternative to the framework of quantum logic. These ideas are of considerable interest for the philosophy of quantum mechanics, a claim which I defend with an extended discussion of their application to our understanding of the philosophical significance of the no hidden variable theorem of Kochen and Specker.Comment: Presented to the 2007 conference, New Directions in the Foundations of Physic

    Application of TVS Models for SEED Simulation of a Variety of TVS Devices

    Get PDF
    Accurate Models of Transient Voltage Suppression (TVS) Devices Are Important for Determining the Suitability of Electrostatic Discharge (ESD) Protection Strategies Early in the Design Process. an Improved TVS Model is Used in the Following Paper to Represent a Variety of TVS Devices, Including a Snapback Device, Non-Snapback Device, and a Varistor. the Models Include Recent Improvements to Represent Conductivity Modulation and the overall Shape of the TVS Device\u27s Transient Response. the Models Are Tuned based on Characterizations of These Protection Devices using a Transmission Line Pulse (TLP) and Are Then Used in a System Efficient ESD Design (SEED) Simulation to Predict the Transient Voltages and Currents in a System Consisting of an Off-Chip TVS, an IC with On-Chip ESD Protection, and a PCB Trace in Between. Simulated Transient Voltage and Current Waveforms Closely Match Measurements Both When Testing the TVS Devices by Themselves and in SEED Simulations. Peak and Quasistatic Currents through the TVS and On-Chip Diode Were Typically Captured within About 10% or Less Across the Devices Tested While Varying Both the Rise Time and Level of the Injected TLP

    Toward multi-focal spot remote focusing two-photon microscopy for high speed imaging

    Get PDF
    This is the final version of the article. Available from SPIE via the DOI in this record.Optical sectioning techniques using two-photon excitation of fluorescent indicators are central to diverse imaging applications. The limitations of the technique are low speed and undesirable specimen agitation. In our design, highspeed axial scanning is carried out by moving a reference objective to axially displace the focal spot without introducing significant spherical aberration and any agitation of the specimen. Further, the system is configured to allow switching between single spot and multiple focal spot remote ...The project is funded by the Medical Research Council through project “MICA: High speed, high resolution imaging of excitable cell networks” (MR/K015877/1)

    The impact of confirmed coronavirus disease 2019 (COVID-19) infection on ambulatory procedures and associated delays in care for asymptomatic patients

    Get PDF
    © 2021 Elsevier Inc. Background: Since the reopening of ambulatory centers, minimal data has been reported regarding positive tests among patients undergoing ambulatory procedures, associated delays in care, and outcomes of patients previously positive for coronavirus disease 2019. Methods: A retrospective observational case series of ambulatory procedures was performed. Records since the reopening of ambulatory centers in New York were searched for patients with positive coronavirus disease 2019 nasal swab results who underwent ambulatory procedures. Chart reviews were conducted to determine coronavirus disease history and hospitalizations, demographic information, procedure details, and 30-day admissions. Results: A total of 3,762 patients underwent ambulatory procedures. Of those, 53 were previously diagnosed with coronavirus disease 2019 but recovered and tested negative at preprocedural testing. Of the 3,709 asymptomatic patients, 37 (1.00%) tested positive during preprocedural testing; 21 patients had their procedures delayed on average 28.6 days until testing negative, while 16 had their procedures performed before testing negative owing to the time sensitivity of the procedure. There were no major complications or 30-day admissions in any of these asymptomatic patients. Three patients tested positive for coronavirus disease after having an ambulatory procedure. Conclusion: Positive tests in asymptomatic patients led to procedure delays of 28.6 days. No patients who underwent ambulatory procedures after a positive coronavirus disease 2019 test had any coronavirus disease-related complications, regardless of whether or not the procedure was delayed until testing negative. Three patients tested positive for coronavirus disease 2019 after having an ambulatory procedure; however, at an average of 19.7 days after, these cases were likely community acquired making the rate of nosocomial infection negligible

    Modeling an ESD Gun Discharge to a USB Cable

    Get PDF
    When an electrostatic discharge (ESD) gun discharges to a USB cable, the routing and quality of the cable impacts the waveform seen at the printed circuit board (PCB) connected to the cable and the ability of an on-board transient voltage suppressor (TVS) to protect sensitive electronics. The impact of cable configurations during ESD gun contact discharge tests was investigated for multiple cable configurations. Injection to a cable pin whose shield is \u27floating\u27 at the injection site can cause a double-peak in the ESD waveform at the PCB and a lower maximum stress level than when the cable shield is connected to the return plane. Poor shielding of the USB connector can further induce a pre-pulse effect, where a smaller ESD pulse arrives at the PCB before the main pulse. This pre-pulse can result in poor firing of the TVS device and thus worsen ESD stress at a sensitive IC. Circuit models were developed to anticipate and explain both of these phenomena. These models were incorporated into a system-level transient simulation including models of a PCB with a TVS and a pair of on-chip diodes. This system-level model was able to predict the quasi-static and peak voltages and currents at the on-chip diode during 1-8 kV ESD contact-discharge tests with various USB cable configurations to within less than 30%. These models were used to develop test and design guidelines to account for the impact of the quality and configuration of a USB cable during an ESD discharge

    Real-time optical manipulation of cardiac conduction in intact hearts

    Get PDF
    Optogenetics has provided new insights in cardiovascular research, leading to new methods for cardiac pacing, resynchronization therapy and cardioversion. Although these interventions have clearly demonstrated the feasibility of cardiac manipulation, current optical stimulation strategies do not take into account cardiac wave dynamics in real time. Here, we developed an all‐optical platform complemented by integrated, newly developed software to monitor and control electrical activity in intact mouse hearts. The system combined a wide‐field mesoscope with a digital projector for optogenetic activation. Cardiac functionality could be manipulated either in free‐run mode with submillisecond temporal resolution or in a closed‐loop fashion: a tailored hardware and software platform allowed real‐time intervention capable of reacting within 2 ms. The methodology was applied to restore normal electrical activity after atrioventricular block, by triggering the ventricle in response to optically mapped atrial activity with appropriate timing. Real‐time intraventricular manipulation of the propagating electrical wavefront was also demonstrated, opening the prospect for real‐time resynchronization therapy and cardiac defibrillation. Furthermore, the closed‐loop approach was applied to simulate a re‐entrant circuit across the ventricle demonstrating the capability of our system to manipulate heart conduction with high versatility even in arrhythmogenic conditions. The development of this innovative optical methodology provides the first proof‐of‐concept that a real‐time optically based stimulation can control cardiac rhythm in normal and abnormal conditions, promising a new approach for the investigation of the (patho)physiology of the heart

    Quantum measurement problem and cluster separability

    Get PDF
    A modified Beltrametti-Cassinelli-Lahti model of measurement apparatus that satisfies both the probability reproducibility condition and the objectification requirement is constructed. Only measurements on microsystems are considered. The cluster separability forms a basis for the first working hypothesis: the current version of quantum mechanics leaves open what happens to systems when they change their separation status. New rules that close this gap can therefore be added without disturbing the logic of quantum mechanics. The second working hypothesis is that registration apparatuses for microsystems must contain detectors and that their readings are signals from detectors. This implies that separation status of a microsystem changes during both preparation and registration. A new rule that specifies what happens at these changes and that guarantees the objectification is formulated and discussed. A part of our result has certain similarity with 'collapse of the wave function'.Comment: 31 pages, no figure. Published versio

    Modality, Potentiality and Contradiction in Quantum Mechanics

    Get PDF
    In [11], Newton da Costa together with the author of this paper argued in favor of the possibility to consider quantum superpositions in terms of a paraconsistent approach. We claimed that, even though most interpretations of quantum mechanics (QM) attempt to escape contradictions, there are many hints that indicate it could be worth while to engage in a research of this kind. Recently, Arenhart and Krause [1, 2, 3] have raised several arguments against this approach and claimed that, taking into account the square of opposition, quantum superpositions are better understood in terms of contrariety propositions rather than contradictory propositions. In [17] we defended the Paraconsistent Approach to Quantum Superpositions (PAQS) and provided arguments in favor of its development. In the present paper we attempt to analyze the meanings of modality, potentiality and contradiction in QM, and provide further arguments of why the PAQS is better suited, than the Contrariety Approach to Quantum Superpositions (CAQS) proposed by Arenhart and Krause, to face the interpretational questions that quantum technology is forcing us to consider.Comment: Published in: New Directions in Paraconsistent Logic, J-Y B\'eziau M. Chakraborty & S. Dutta (Eds.), Springer, in press. arXiv admin note: text overlap with arXiv:1404.518
    • 

    corecore